Bandwidth
|
DC to 200MHz (-3dB)
|
|
|
|
Attenuation Ratio
|
1/10
|
|
|
|
Accuracy
|
+/- 1%
|
|
|
|
Rise Time
|
1.75ns
|
|
|
|
Input Impedance
|
500Kohm//7pF each side to
ground
|
|
|
|
Input Voltage
|
|
|
|
¡@-Differential Range
|
+/- 20V(DC+Peak AC) |
|
|
|
¡@-Common Mode Range
|
+/-60V(DC+Peak AC) |
|
|
|
¡@-Absolute Max. Voltage
(either input to ground)
|
+/-60V(DC+Peak AC)
|
|
|
|
Output Voltage
|
|
|
|
¡@- Swing
|
+/-2V (into 50ohm load)
|
|
|
|
¡@-Offset (typical)
|
<+/-2mV
|
|
|
|
¡@-Noise (typical)
|
0.3mVrms
|
|
|
|
¡@-Source Impedance (typical)
|
50 ohm (for using 50ohm input system oscilloscope)
|
|
|
|
CMRR (typical)
|
-80dB @60Hz, -50dB @10MHz
|
|
|
|
Power Requirements (Four options of power sources)
|
Mains adaptor (6VDC/90mA or 9VDC/70mA) or Regulated 15VDC/100mA mains adaptor
or Power leads or USB power cord
|
|
|
|
Optional Extension Plugs for Mains Adaptor
|
|
|
|
-Input
|
One jack of 1A current rating
|
|
|
|
-Output
|
Three plugs of 1A current rating
|
|
|
|
Ambient Operating Temperature
|
-10 to 40 degree centigrade
|
|
|
|
Ambient Storage Temperature
|
-30 to 70 degree centingrade
|
|
|
|
Ambient Operating Humidity
|
25 to 85% RH
|
|
|
|
Ambient Storage Humidity
|
25 to 85% RH
|
|
|
|
Length of BNC Cable
|
125cm
|
|
|
|
length of Input Leads
|
50cm
|
|
|
|
Weight
|
300gms
|
|
|
|
Dimension(LxWxH)
|
111mm x 22mm x 14mm
|
|